електронна поща

Sales@CableAndConnector.com

Моб/WeChat

+86-153-9700-4205

12 Core Aerial Fiber Cable

12 Core Aerial Fiber Cable

Product name:12 Core Aerial Fiber CableModel:CAC-ASU-80M-4/12FFiber cores:4~12 Core Fiber is OptionalSpan:80MOuter sheath material:PEInstallation Temperature:-10℃ ~ +60℃.
Изпрати запитване
Чат сега
Описание
Технически параметри
Description of 12 Core Aerial Fiber Cable

Aerial Fiber Cable also Called the ASU cable.Aerial Fiber Cable is a lighter and more affordable alternative to ADSS cable,The single loose tube design made the cable with lighter weight the two FRP strength providing the good Mechanical performance, easy for installation So that it is getting more and more popular from the ISP company,Strength Member:FRP,Fiber cores:4~12 Core Fiber is Optional,Span:80M ASU Cable,Cable MAT Short Term:1.4KN,Max. crush resistance (Short term):1000 N/100mm,Min. bending radius (Installation):25 times the cable diameter,Min. bending radius (Operation):15 times the cable diameter,Installation Temperature:-10℃ ~ +60℃.

 of 12 Core Aerial Fiber Cable

3-2logo750-9logo

750-10logo3--750logo

Max. crush resistance

1000 N/100mm

Min. bending radius

25 times the cable diameter

15 times the cable diameter

-30℃ ~ +70℃

-10℃ ~ +60℃

-30℃ ~ +70℃

IEC 60794-1-2-

E1

Length of cable: about 50m

Load time>=1 min

Fiber strain <= 0.33%.

Loss change <= 0.1dB@1550nm after test. No fiber break

and no sheath damage.

Crush Test IEC 60794-1-2-E3

Load: Short term crush Load time: >= 1min

Loss change <= 0.1dB@1550nm after test. No fiber break

and no sheath damage.

Impact Test IEC 60794-1-2-E4

Radius: 300 mm

Points of impact: 3

Times of per point: 1

Impact energy: 10J

Loss change <= 0.1dB/km@1550nm. No fiber break and

no sheath damage.

60794-1-2-E6

Bending radius: 20 x OD No. of cycle: 10

Loss change <= 0.1dB/km@1550nm. No fiber break and

no sheath damage.

IEC 60794-1-2-

E7

Length: 1m

Twist angle: ±90℃

No. of cycle: 10

Loss change <= 0.1dB/km@1550nm. No fiber break and

no sheath damage.

Cable bend IEC 60794-1-2-E11

Diameter of mandrel:20 x OD

-Number of turns:10

-Number of cycles:5

Loss change <= 0.1dB/km@1550nm. No fiber break and

no sheath damage.

60794-1-2-F5

Height of water: 1m

Sample length: 3m Time: 24h

No water leak from the cable core of the opposite end.

60794-1-2-F1

Temperature: -30℃~+70℃

Time of each step: 12h

Number of cycle: 2

Loss change <= 0.1dB/km@1550nm. No fiber break and

no sheath damage.

 

1 Each single cable length been wound on an iron stand-wooden composite or pure wooden drum.

2 Standard drum length is 4000m/5000m with ±2%,other length is also available.

3 At least 3m of cable inner end should be reserved for testing.

4 Covered by plastic buffer sheet.

5 Sealed by strong wooden battens.

 

Популярни тагове: 12 core aerial fiber cable, China 12 core aerial fiber cable manufacturers, suppliers, factory